Vertec Home Page
Vertec Home Page
local equipment rooms, DNV, control cabins
hire cabins, switchgear, ATEX, Norsok, tactical shelters
process packages
hire cabins and equipment rental
HVAC, air conditioning & refrigeration
Vertec case studies
 

Site Map

Legal Information

1st Point quality standards

ISO 9001 accreditation

© Vertec 2005

Site by Artech

Fire protected (A60 – H60) cabins  
Vertec Home Page Specialist manufacturing services Vertec News Vertec Vacancies Contact Vertec Offshore oil and gas industries glossary Vertec links Vertec Site Map
Specialist manufacturing services to the offshore oil and gas industries
Fire protected cabins to international standards
EEMUA I58
BS EN 12079
DNV 2.7-1
DNV 2.7-2
Norsok
P.E.D
ATEX / IEC
ASME VIII
ASME 31.3B
PD5500
Fire Protection (A60/H60)
ISO 9000
BS EN ISO 9001:2000
local equipment rooms, DNV, control cabins

Mobil – Beryl Alpha Platform
Baker Hughes Centrilift – Santos
Kellogg Brown & Root/ExxonMobil
Petreco International/AMEC

Kellogg Brown & Root/ExxonMobil – Corrosion Inhibitor Package

Project

Vertec undertook the design, manufacture and testing of 1-No. Corrosion Inhibitor Package for the Atlantic & Cromarty Project.

Overview

Corrosion Inhibitor is injected at a flow range of 0.19 Ltrs/Hr to 0.56 Ltrs/Hr at a maximum pressure of 1.5 BarG offering protection to upsteam MEG Injection Pumps.

KBR Corrosion Inhibitor

System Description

The package comprised a storage tank, common suction line c/w isolation ball valves, strainer and pump setting gauge. Corrosion inhibitor is injected via two Pulsafeeder Electrically driven metering pumps (one duty, one stand-by) and discharged via a common line comprising pressure relief valves, pressure gauges and ball valves. Corrosion inhibitor leaves the skid via a 1.5" NB ANSI 150LB WNRF Flange. The tank level is controlled by a Radar Wave Level Transmitted and visually by a magnetic level gauge.

Vertec Scope of Supply

Fabricate and paint structural steel skid, pipe supports grating etc.
Fabricate 0.5m stainless steel storage tank.
Supply all skid instrumentation including pumps, valves, tank ancillaries, etc.
Installation of all equipment including electrical and instrumentation.
Testing of completed package.
Compile comprehensive manufacturing data book.